-40%

Dell PowerConnect 6248P PoE 48-Port Managed Gigabit Ethernet Switch 0PK463 4xSFP

$ 52.79

Availability: 100 in stock
  • All returns accepted: Returns Accepted
  • Type: Ethernet Switch
  • Return shipping will be paid by: Seller
  • Condition: This is a USED WORKING item in GOOD cosmetic condition that IS THOROUGHLY TESTED and is GUARANTEED WORKING
  • MPN: PowerConnect 6248P
  • Restocking Fee: No
  • Item must be returned within: 30 Days
  • Brand: Dell
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Model: PowerConnect 6248P

    Description

    TESTING & COSMETIC NOTES:
    This is a USED WORKING item in GOOD cosmetic condition that IS THOROUGHLY TESTED and is GUARANTEED WORKING
    This unit has been factory reset, view console log for more info.
    COMPONENTS INCLUDED IN THIS AUCTION:
    • (1) - DELL POWERCONNECT 6248P POE 48-PORT MANAGED GIGABIT ETHERNET SWITCH 0PK463 10GE SFP+ PK463
    • (1) - PAIR OF RACKMOUNT EARS
    • (1) - POWER CORD
    REPLACEMENT or MONEY BACK GUARANTEE:
    When you receive a Guaranteed item from OC Depot, it should perform as described. In the rare situation that this is not the case, we will send a replacement upon safe return of the original item within 30 days of receiving the item. If a replacement is not available we will honor the terms of our Money-Back Guarantee.
    ADDITIONAL INFORMATION:
    The following is the Console Log from this item:
    Boot Menu Version: 21 November 2008
    CPU Card ID: 0x508541
    /DskVol// - disk check in progress ...
    /DskVol// - Volume is OK
    total # of clusters: 15,147
    # of free clusters: 4,976
    # of bad clusters: 0
    total free space: 9,952 Kb
    max contiguous free space: 10,162,176 bytes
    # of files: 24
    # of folders: 1
    total bytes in files: 20,311 Kb
    # of lost chains: 0
    total bytes in lost chains: 0
    volume descriptor ptr (pVolDesc): 0xffeea80
    cache block I/O descriptor ptr (cbio): 0xffeeb60
    auto disk check on mount: DOS_CHK_REPAIR | DOS_CHK_VERB_2
    max # of simultaneously open files: 22
    file descriptors in use: 0
    # of different files in use: 0
    # of descriptors for deleted files: 0
    # of obsolete descriptors: 0
    current volume configuration:
    - volume label: NO LABEL ; (in boot sector: )
    - volume Id: 0xd2
    - total number of sectors: 60,716
    - bytes per sector: 512
    - # of sectors per cluster: 4
    - # of reserved sectors: 1
    - FAT entry size: FAT16
    - # of sectors per FAT copy: 60
    - # of FAT table copies: 2
    - # of hidden sectors: 4
    - first cluster is in sector # 136
    - Update last access date for open-read-close = FALSE
    - directory structure: VFAT
    - root dir start sector: 121
    - # of sectors per root: 15
    - max # of entries in root: 240
    FAT handler information:
    ------------------------
    - allocation group size: 2 clusters
    - free space on volume: 10,190,848 bytes
    Boot Menu Version: 21 November 2008
    Select an option. If no selection in 10 seconds then
    operational code will start.
    1 - Start operational code.
    2 - Start Boot Menu.
    Select (1, 2):
    Operational Code Date: Tue Nov 25 13:19:13 2008
    Uncompressing.....
    50% 100%
    ||||||||||||||||||||||||||||||||||||||||||||||||||
    Attaching interface lo0...done
    Adding 47386 symbols for standalone.
    /DskVol// - disk check in progress ...
    dosChkLib : CLOCK_REALTIME is being reset to FRI APR 22 08:01:40 2005
    Value obtained from file system volume descriptor pointer: 0xffc00f0
    The old setting was THU JAN 01 00:00:03 1970
    Accepted system dates are greater than THU DEC 27 00:00:00 1990
    /DskVol// - Volume is OK
    total # of clusters: 15,147
    # of free clusters: 4,975
    # of bad clusters: 0
    total free space: 9,950 Kb
    max contiguous free space: 10,162,176 bytes
    # of files: 25
    # of folders: 1
    total bytes in files: 20,312 Kb
    # of lost chains: 0
    total bytes in lost chains: 0
    volume descriptor ptr (pVolDesc): 0xffc00f0
    cache block I/O descriptor ptr (cbio): 0xffc01d0
    auto disk check on mount: DOS_CHK_REPAIR | DOS_CHK_VERB_2
    max # of simultaneously open files: 22
    file descriptors in use: 0
    # of different files in use: 0
    # of descriptors for deleted files: 0
    # of obsolete descriptors: 0
    current volume configuration:
    - volume label: NO LABEL ; (in boot sector: )
    - volume Id: 0xd2
    - total number of sectors: 60,716
    - bytes per sector: 512
    - # of sectors per cluster: 4
    - # of reserved sectors: 1
    - FAT entry size: FAT16
    - # of sectors per FAT copy: 60
    - # of FAT table copies: 2
    - # of hidden sectors: 4
    - first cluster is in sector # 136
    - Update last access date for open-read-close = FALSE
    - directory structure: VFAT
    - root dir start sector: 121
    - # of sectors per root: 15
    - max # of entries in root: 240
    FAT handler information:
    ------------------------
    - allocation group size: 2 clusters
    - free space on volume: 10,188,800 bytes
    Timebase: 66.666666 MHz, MEM: 266.666664 MHz, PCI: 66.666666 MHz, CPU: 533.33332
    8 MHz
    SOC unit 0 attached to PCI device BCM56314_A0
    SOC unit 1 attached to PCI device BCM56314_A0
    Adding BCM transport pointers
    Configuring CPUTRANS TX
    Configuring CPUTRANS RX
    hpc - No stack ports. Starting in stand-alone mode.
    MonitorTask - Active
    DebugMonitorTask - Active
    (Unit 1 - Waiting to select management unit)>
    Applying configuration, please wait ...
    Welcome to Dell Easy Setup Wizard
    The Setup Wizard guides you through the initial switch configuration, and
    gets you up and running as quickly as possible. You can skip the setup
    wizard, and enter CLI mode to manually configure the switch. You must
    respond to the next question to run the setup wizard within 60 seconds,
    otherwise the system will continue with normal operation using the default
    system configuration.Note: You can exit the setup wizard at any point
    by entering [ctrl+z].
    Would you like to run the setup wizard (you must answer this question within
    60 seconds)? [Y/N] n
    Thank you for using Dell Easy Set up Wizard. You will now enter CLI mode.
    Applying configuration, please wait ...>
    console>en
    console#show ver
    Image Descriptions
    image1 : default image
    image2 :
    Images currently available on Flash
    --------------------------------------------------------------------
    unit image1 image2 current-active next-active
    --------------------------------------------------------------------
    1 2.2.0.3 2.2.0.3 image1 image1
    console#show system
    System Description: Dell Ethernet Switch
    System Up Time: 0 days, 00h:01m:27s
    System Contact:
    System Name:
    System Location:
    Burned In MAC Address: A4BA.DB75.F3BE
    System Object ID: 1.3.6.1.4.1.674.10895.3013
    System Model ID: PCT6248P
    Machine Type: PowerConnect 6248P
    Temperature Sensors:
    Unit Temperature (Celsius) Status
    ---- --------------------- ------
    1 30 OK
    Fans:
    Unit Description Status
    ---- ----------- ------
    1 Fan 1 OK
    1 Fan 2 OK
    1 Fan 3 OK
    1 Fan 4 OK
    1 Fan 5 OK
    Power Supplies:
    Unit Description Status Source
    ---- ----------- ----------- ------
    1 Main OK AC
    1 Secondary Failure DC
    console#exit