-40%

Cisco WS-C3750G-12S-S 12 SFP Ports Gigabit Switch 3750G-12S-S 1 YEAR WARRANTY

$ 36.95

Availability: 33 in stock
  • Return shipping will be paid by: Seller
  • Number of LAN Ports: 12
  • Ethernet Technology: Gigabit Ethernet (1000-Mbit/s)
  • MPN: WS-C3750G-12S-S
  • Form Factor: Rack-Mountable
  • Layer: 3
  • Country/Region of Manufacture: Uganda
  • Type: Ethernet Switch
  • Condition: Please see pictures & Full Test Report!!!!90 Day Warranty!!! c3750-ipservicesk9-mz.122-55.SE9.bin and also WEB interface files are installed!!!”
  • Restocking Fee: 20%
  • Maximum Data Transfer Rate: 1000Mbps/1Gbps
  • Custom Bundle: No
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Model: WS-C3750G-12S-S
  • Item must be returned within: 30 Days
  • Brand: Cisco
  • Modified Item: No
  • Non-Domestic Product: No

    Description

    Included In this Auction
    Model Number
    : Cisco Catalyst
    WS-C3750G-12S-S
    Quantity Available: 100
    Quantity: ONE (1)
    Warranty: 1 Year
    1 Rack Mount Kit
    1 Power cord
    1 Console cable
    TEST REPORT
    SHOW ENVIRONMENT  ALL
    Switch#sh env all
    FAN is OK
    TEMPERATURE is OK
    SW  PID                 Serial#     Status           Sys Pwr  PoE Pwr  Watts
    --  ------------------  ----------  ---------------  -------  -------  -----
    1  Built-in                                         Good
    SW  Status          RPS Name          RPS Serial#  RPS Port#
    --  -------------   ----------------  -----------  ---------
    1   Not Present     <>
    Switch#sh  got vend id vend spec. info ret: succeedpost
    SHOW FLASH:
    Switch# sh flash
    Directory of flash:/
    2  -rwx    13009047   Mar 1 1993 01:09:01 +00:00  c3750-ipservicesk9-mz.122-55.SE9.bin
    3  -rwx        1048   Mar 1 1993 00:01:46 +00:00  multiple-fs
    15998976 bytes total (2987008 bytes free)
    SHOW POST
    Switch#sh post
    Stored system POST messages:
    Switch 1
    ---------
    POST: CPU MIC register Tests : Begin
    POST: CPU MIC register Tests : End, Status Passed
    POST: PortASIC Memory Tests : Begin
    POST: PortASIC Memory Tests : End, Status Passed
    POST: CPU MIC interface Loopback Tests : Begin
    POST: CPU MIC interface Loopback Tests : End, Status Passed
    POST: PortASIC RingLoopback Tests : Begin
    POST: PortASIC RingLoopback Tests : End, Status Passed
    POST: PortASIC CAM Subsystem Tests : Begin
    POST: PortASIC CAM Subsystem Tests : End, Status Passed
    POST: PortASIC Stack Port Loopback Tests : Begin
    POST: PortASIC Stack Port Loopback Tests : End, Status Passed
    POST: PortASIC Port Loopback Tests : Begin
    POST: PortASIC Port Loopback Tests : End, Status Passed
    SHOW VERSION
    Switch#sh ver
    Cisco IOS Software, C3750 Software (C3750-IPSERVICESK9-M), Version 12.2(55)SE9, RELEASE SOFTWARE (fc1)
    Technical Support:
    Copyright (c) 1986-2014 by Cisco Systems, Inc.
    Compiled Mon 03-Mar-14 22:45 by prod_rel_team
    Image text-base: 0x01000000, data-base: 0x02F00000
    ROM: Bootstrap program is C3750 boot loader
    BOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.2(44)SE5, RELEASE SOFTWARE (fc1)
    Switch uptime is 2 minutes
    System returned to ROM by power-on
    System image file is "flash:/c3750-ipservicesk9-mz.122-55.SE9.bin"
    This product contains cryptographic features and is subject to United
    States and local country laws governing import, export, transfer and
    use. Delivery of Cisco cryptographic products does not imply
    third-party authority to import, export, distribute or use encryption.
    Importers, exporters, distributors and users are responsible for
    compliance with U.S. and local country laws. By using this product you
    agree to comply with applicable laws and regulations. If you are unable
    to comply with U.S. and local laws, return this product immediately.
    If you require further assistance please contact us by sending email to
    cisco WS-C3750G-12S (PowerPC405) processor (revision S0) with 131072K bytes of memory.
    Processor board ID FDO1229Y1YJ
    Last reset from power-on
    1 Virtual Ethernet interface
    12 Gigabit Ethernet interfaces
    The password-recovery mechanism is enabled.
    512K bytes of flash-simulated non-volatile configuration memory.
    Base ethernet MAC Address       : 00:22:90:54:F4:00
    Motherboard assembly number     : 73-9678-08
    Power supply part number        : 341-0048-03
    Motherboard serial number       : FDO12290PW4
    Power supply serial number      : LIT122604MX
    Model revision number           : S0
    Motherboard revision number     : A0
    Model number                    : WS-C3750G-12S-S
    System serial number            : FDO1229Y1YJ
    Top Assembly Part Number        : 800-25856-05
    Top Assembly Revision Number    : A0
    Version ID                      : V07
    CLEI Code Number                : CNM82V0GRA
    Hardware Board Revision Number  : 0x06
    Switch Ports Model              SW Version            SW Image
    ------ ----- -----              ----------            ----------
    *    1 12    WS-C3750G-12S      12.2(55)SE9           C3750-IPSERVICESK9-M
    Configuration register is 0xF
    SFP GIGABYTE PORTS
    (TESTED WITH GLC-SX-MM FIBER OPTIC CABLES)
    *Mar  1 00:04:32.269: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/1, changed state to up
    *Mar  1 00:04:32.285: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/2, changed state to up
    *Mar  1 00:04:50.447: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/1, changed state to down
    *Mar  1 00:04:50.489: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/2, changed state to down
    *Mar  1 00:04:51.445: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/1, changed state to down
    *Mar  1 00:04:51.487: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/2, changed state to down
    *Mar  1 00:05:25.117: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/3, changed state to up
    *Mar  1 00:05:25.696: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/4, changed state to up
    *Mar  1 00:05:26.123: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/3, changed state to up
    *Mar  1 00:05:26.702: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/4, changed state to up
    *Mar  1 00:05:48.479: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/3, changed state to down
    *Mar  1 00:05:48.479: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/4, changed state to down
    *Mar  1 00:05:49.477: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/3, changed state to down
    *Mar  1 00:05:49.486: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/4, changed state to down
    *Mar  1 00:06:14.710: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/6, changed state to up
    *Mar  1 00:06:15.281: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/5, changed state to up
    *Mar  1 00:06:15.717: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/6, changed state to up
    *Mar  1 00:06:16.287: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/5, changed state to up
    *Mar  1 00:06:30.514: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/5, changed state to down
    *Mar  1 00:06:30.523: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/6, changed state to down
    *Mar  1 00:06:31.513: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/5, changed state to down
    *Mar  1 00:06:31.521: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/6, changed state to down
    *Mar  1 00:06:53.046: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/7, changed state to up
    *Mar  1 00:06:53.625: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/8, changed state to up
    *Mar  1 00:06:54.053: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/7, changed state to up
    *Mar  1 00:06:54.632: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/8, changed state to up
    *Mar  1 00:07:08.204: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/7, changed state to down
    *Mar  1 00:07:08.213: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/8, changed state to down
    *Mar  1 00:07:09.203: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/7, changed state to down
    *Mar  1 00:07:09.211: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/8, changed state to down
    *Mar  1 00:07:32.137: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/10, changed state to up
    *Mar  1 00:07:32.800: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/9, changed state to up
    *Mar  1 00:07:33.144: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/10, changed state to up
    *Mar  1 00:07:33.806: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/9, changed state to up
    *Mar  1 00:07:45.634: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/9, changed state to down
    *Mar  1 00:07:45.634: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/10, changed state to down
    *Mar  1 00:07:46.633: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/9, changed state to down
    *Mar  1 00:07:46.641: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/10, changed state to down
    *Mar  1 00:07:59.861: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/12, changed state to up
    *Mar  1 00:08:00.440: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/11, changed state to up
    *Mar  1 00:08:00.868: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/12, changed state to up
    *Mar  1 00:08:01.447: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/11, changed state to up
    *Mar  1 00:08:20.984: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/11, changed state to down
    *Mar  1 00:08:20.984: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/12, changed state to down
    *Mar  1 00:08:21.982: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/11, changed state to down
    *Mar  1 00:08:21.991: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/12, changed state to down
    STACK LOOP-BACK PORT TEST
    (TESTED WITH STACK CABLES)
    *Mar  1 00:09:20.090: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state UP
    *Mar  1 00:09:20.090: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state UP
    *Mar  1 00:09:30.190: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN
    *Mar  1 00:09:30.190: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
    **NOTE FOR BUYER**
    If you buyer has any problem with product purchase, please contact us immediately we will resolve it quickly, please don't leave OPEN CASE on ebay or leave Negative feedback before contact us.