-40%

4 Port IEEE802.3at Gigabit High Power over Ethernet Midspan, PHIHONG - used

$ 9.24

Availability: 81 in stock
  • Number of WAN Ports: 4
  • Return shipping will be paid by: Buyer
  • Country/Region of Manufacture: China
  • Form Factor: Standalone
  • Ethernet Technology: Gigabit Ethernet (1000-Mbit/s)
  • All returns accepted: Returns Accepted
  • Condition: Used
  • Refund will be given as: Money Back
  • Brand: PHIHONG
  • Type: Ethernet Switch
  • Item must be returned within: 14 Days
  • Model: Phihong IEEE802 .3
  • Restocking Fee: No
  • Product Line: Enterprise
  • Interface: Ethernet (RJ-45)
  • Number of LAN Ports: 4

    Description

    4 Port IEEE802.3at Gigabit High Power over Ethernet Midspan Phihong used and untested, no adapter.
    - Compliant with the IEEE802.3atStandard
    • Full Power of 134.4W—33.6W PerPort• 10/100/1000 Base-T Compatible
    • No Power Management Required
    • Cisco AP1250 Full Power Support
    • Full Protection OCP, OVP
    • Optional Kit available for a 19” RackMount1
    INPUT:AC InputVoltage Range 90 to 264VAC
    Input Frequency47-63Hz
    Input Current2.5A (RMS) max for 90VAC1.3A (RMS) max for 240VAC
    Leakage Current3.5mA max @ 254VAC 60HzAC
    Inrush Current30A (RMS) max for 115VAC60A (RMS) max for 230VAC
    OUTPUT:Total Output Power33.6W per port
    Ripple and Regulation100mV maxEfficiency275% (typical) at max load, 120VAC 60HzHold-up Time10mS min. 120VAC, max loadTransient O/P Voltage Protection60V max at switch on/off at any AC line Phase
    Turn-On Delay Time3 sec max at max load,120VAC 60Hz,25HzENVIRONMENTAL:TemperatureOperation 0°C to +40°CNon-operation -25°C to +65°CHumidity 5 to 90%EMCFCC Class BEN55022 Class BIsolation TestPrimary to Secondary: 4242VDC, 1 minutePrimary to Ground: 2121VDC, 1 minuteSecondary to Ground: 2121VDC, 1 minuteImmunity EN50082-1ESD: EN61000-4-2, Level 3RS: EN61000-4-3, Level 2EFT: EN61000-4-4, Level 2Surge: EN61000-4-5, Level 3CS: EN61000-4-6, Level 2Voltage Dips EN61000-4-11Harmonic: EN61000-3-2, Class AIEEE 802.3at InteroperabilityUNH Interoperability report available onrequestFEATURES:CiscoNo extern parts required for Legacy devices:VoIP Phones:7910, 7912, 7940, 7960Access Points:1040, 1140, 1250, 1260, 3500Over Voltage/Current, Short CircuitProtectionOutputs equipped with short circuit protectionand overload protection as per 802.3atspecifications. The output can be shortedpermanently without damageOver Temperature ProtectionAutomatic shutdown without damageIndicatorsGreen LED: Power detected “ON”Yellow LED: Fault detectedInput ConnectorAC Input IEC320 C14